Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13668620
| No.13668620
- Product Categories
- Friendly Links
| Information Name: | Shenyang misfire cement mortar factory / production and sales |
| Published: | 2015-05-08 |
| Validity: | 300 |
| Specifications: | 50 |
| Quantity: | 1000.00 |
| Price Description: | |
| Detailed Product Description: | Misfire misfire hardener mortar Dian Dian cement mortar fire (explosion proof frictional sparks) misfire cement mortar, special hardener basic instructions misfire misfired mortar factory direct special dry mortar-built Industrial Supply:! Shilong Li Gong 13,331,056,879 18,311,209,002 Welcome to inquire, factory direct, ex-factory price, low price QQ85574781 misfire mortar (explosion-proof anti-friction sparking) misfired mortar description: mainly by dolomite, quartz sand, special additives and special cement and other components. This product has not pyrophoric and high wear resistance, impact resistance, moisture resistance, decorative, can not afford to powder, easy construction, and encountered no impact or friction sparks. Do not get angry cement mortar, special hardener misfire misfire Features Floor Features: 1. floor by metal friction does not produce sparks. 2. Enhanced wear resistance and strength, high density concrete floors and dust-proof, long-lasting, dense surface never fade. Do not get angry mortar (proof anti-friction sparking) 3. Pre-packaged product does not require adding other materials. 4. grease resistant, easy to clean. 5. New poured concrete surface and the whole combination of short construction period. 6. The non-metallic aggregate humid environment does not rust, can increase the smoothness of the table after floor after continuous use. [Misfire cement mortar, special misfire hardener] service is not angry wear-resistant floor construction program: misfire mortar (explosion-proof anti-friction sparking) 1, wipe smooth loft building structure according to the reference ink line (such as walls + 50cm line), with the water level in the fix floor area pouring concrete pouring predetermined thickness, set the horizontal elevation mark, and careful examination, to control the maximum deviation irregularities within 3-5mm. 2, concrete pouring (1) before pouring concrete foundations in the water to keep it moist. To reduce bleeding, should control water-cement ratio and slump, concrete chute with the use of artificial discharge, should not be used to pump. (2) as a pouring concrete to level, at the local level has not reached the use of concrete material filled and vibrated, prohibited the use of mortar repair. Using a plate vibrator vibrated, and with a special steel rolling drum repeatedly, columns, corners and other parts wipe with a wooden racket pulp. After rising to the surface of the concrete screed grout at least 3 mm thick. (3) concrete pouring is completed, the use of wear-resistant materials after construction began hose or vacuum device other bleeding to repeat two more times. Wear-resistant materials of construction before mid-stage construction work should wear flat shoes into the late stages of the job should wear waterproof shoes into the paper. [Misfire cement mortar, special hardener misfire misfired mortar] Scope Adaptation: (explosion-proof anti-friction sparking) · Application of Light Industry Machinery Plant friction shop electronic precision instrument manufacturing workshop of oil and gas deposits library misfired mortar high-voltage transformer manufacturing plant warehouse logistics flammable cargo stacking area laboratory product features enhanced wear resistance and strength of the concrete floor. Floor friction does not produce sparks. High-density, pre-packaged goods can not afford to dust mixed with other materials and does not need to newly poured concrete surfaces entirety short construction period lasting, dense surface never fade resistant grease, easy to clean non-metallic aggregate humid environment is not corroded by the continuous surface After use can increase the smoothness of inflammable and explosive materials production workshop and store warehouses. [Misfire cement mortar, special misfire hardener] Specifications steps: Do not get angry mortar (explosion-proof anti-friction sparking) First, the surface treatment 1, completion of the new industrial floor must be after a certain amount of conservation before construction, about 28 days. 2, remove laitance surface adhesion of the old paint and garbage debris. 3, the elimination of surface oil, expressed in grams of oil Wang cleaning agent. 4, clear water, and a dry place to dry thoroughly. 5, clean the surface of the need to use clean sweepers and large vacuum cleaner to complete. 6, flat surface allows the gap to 2 ~ 2.5mm, moisture content below 6%, PH value of 6 to 80. 7, floor surface roughening, clean grinding machine required to complete and thoroughly cleaned with a vacuum cleaner. 8 holes on the floor surface and obvious depression applications: (1 3 Antistatic mortar) to fill Scraping, hard work, sanding dust. Second, clean up the screed leveling layer construction, ballast for floating dust or broken pieces to be cleaned ruled. For the surface layer of mortar and leveling layer bonded firmly three to bottom with four anti-static grounding wire mesh, 30 thick layer of cement mortar antistatic V. 20 thick anti-static surface layer of cement mortar six, do antistatic surface hardener. Construction of 1 anti-static hardener level is made in anti-static floor and remove mortar bleeding after starting work, carried to the surface of the processing is completed. Construction by qualified personnel using a mechanical trowel job is completed. 2, for the antistatic hardener spreading evenly, should calculate the amount of material (5KG / m) before construction, and put in place; antistatic Mortar initial setting stage, even the laitance concrete surface slope broken, then the floor hardener spread evenly in the face of anti-static mortar; antistatic hardener required in two (2 / 3,1 / 3), spreading evenly, spreading in the direction of the second and first vertical, After Isaac finished, carry out the installation disc mechanical trowel work, mechanical trowel work should be criss-crossing each; 3, after the operation, according to the anti-static case hardened mortar, at least three times the disk is not mounted mechanical trowel Smoother operations, changes in operating speed and angle iron mechanical trowel of mortar should be considered anti-static floor sclerosis was adjusted trowel work has been completed to the floor surface machining. Specifications 1, surface impedance (test point from 900mm-1000mm) 2, relative humidity of 40% -70%, the resistance value between the point requires 5.0 × 104 ~ 1.0 × 109Ω, 3, relative humidity less than 30% required resistance value between the point 106 ~ 108Ω. 4, to network density 6m * 6m, to net copper width 15-20mm, thickness 0.05-0.08mm. 5, self-leveling anti-static mechanical properties and surface appearance of the quality of performance in accordance with specifications. [Misfire cement mortar, special misfire curing hardener Packing instructions: Use an antistatic floor mortar after hardening, to get the physical performance of the design, proper screening is essential, when complete mechanical trowel 12 hours, the surface should be use floor wax conservation, guarantee the steady growth of wear-resistant floor strength. Note construction temperature not lower than 5 ℃. Construction of the base surface of compacted thickness of not less than 3 mm. Under hot and dry conditions, the construction needs to reach a good surface to prevent excessive drying. Note: Do not get angry mortar (proof anti-friction sparking) 1. raw materials pyrophoric controlled substances 2. Storage and transportation of all raw materials in the construction process should be non-mixed friction collision easy to produce sparks of substances (such as various metals and other types of stones). 3. Before the raw material into the mixer, all the ingredients were once again the best iron absorption examination, particularly cement, because cement is often possible when mixed with some of the grinding mill grinding debris and iron. |
Admin>>>
You are the 15437 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Shun Jian Industrial Engineering Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 15437 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Shun Jian Industrial Engineering Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

